magnetic latching relay

Name:magnetic latching relay

Brand:MGRELAY/BETA

Optional Sockets:

Refer to BTA3 socket instructions (e.g., BTA3-11A).

Wiring Diagrams Available:

  • DC Dual Coil:1C (SPDT) and 2C (DPDT)
  • DC Single Coil:2C (DPDT) and 3C (3PDT)
  • AC Single Coil:1C, 2C, and 3C configurations

The BTA2G is a permanent magnetic latching relay designed for applications where energy efficiency and maintained state without continuous power are essential. Utilizing a magnetic latching mechanism, the relay remains in its last switched position without requiring a constant coil supply, reducing power consumption and heat generation. Available in single- or double-coil configurations and with gold-plated contacts for reliability, it is ideal for energy management systems, smart meters, backup power controls, and other applications where state retention is critical.

Key Features:

  • Magnetic Latching:Maintains position without continuous power
  • Double-Coil or Single-Coil Design:For set/reset operation or pulsed control
  • High Contact Capacity:10A switching
  • Contact Forms:1C (SPDT) or 2C (DPDT)
  • Gold-Plated Contacts:Enhanced conductivity and durability
  • Manual Test Button:Allows circuit testing without coil power
  • LED Indicator:Shows relay status (AC: red, DC: green)
  • Multiple Housing Options:Standard, side flange, top flange, and clamp rail housings
  • Wide Coil Voltage Range:6–110VDC, 6–240VAC

Model Description:

CodeDescription
BTA2GBase Model – Magnetic Latching
1C / 2CContact Form (1C=SPDT, 2C=DPDT)
(Blank)Contact Load: 10A
S1 / S2Terminal Type (S1:4.8×0.8mm, S2:4.8×0.5mm)
C / C1 / C3 / C4Shell Type (C=Standard, C1=Side Flange, C3=Top Flange, C4=Clamp Rail)
LLED Indicator (AC=Red, DC=Bipolar Green)
SSingle Coil
DDouble Coil

Coil Specifications (at 23°C):

Coil TypeRated VoltageCoil Resistance (Ω) – 1C/2CPickup/Release Voltage
DC Double Coil6VDC22Ω ±10%≤75%
12VDC90Ω ±10%≤75%
24VDC350Ω ±10%≤75%
48VDC1400Ω ±10%≤75%
110VDC9000Ω ±10%≤75%
AC Single Coil6VAC32Ω ±10%≤80%
12VAC120Ω ±10%≤80%
24VAC472Ω ±10%≤80%
48VAC1800Ω ±10%≤80%
120VAC10000Ω ±10%≤80%
240VAC40000Ω ±10%≤80%
DC Single Coil6VDC32Ω ±10%≤75%
12VDC120Ω ±10%≤75%
24VDC472Ω ±10%≤75%
48VDC1800Ω ±10%≤75%
110/125VDC9000Ω ±10%≤75%

Note: Maximum withstand voltage = 110% of rated voltage for short periods.

Contact Specifications:

Parameter1C2C
Resistive Load10A @ 28VDC, 120/240/277VACSame as 1C
Motor Load1/3 HP @ 120VAC; 1/2 HP @ 240VACSame as 1C
Switching Power448W, 4432VASame as 1C
Contact MaterialAgSnO₂ AlloyAgSnO₂ Alloy
Initial Contact Resistance≤50mΩ≤50mΩ
Electrical Life100,000 operations100,000 operations
Mechanical Life10,000,000 operations10,000,000 operations

General Electrical & Mechanical Parameters:

ParameterValue
Pickup Voltage (23°C)DC: ≤80%, AC: ≤85% of rated voltage
Release Voltage (23°C)DC: ≤80%, AC: ≤85% of rated voltage
Max. Voltage110% of rated voltage
Coil PowerDC: 1.2–1.64W, AC: 2.0–3.0VA
Pickup TimeAC: ≤30ms, DC: ≤20ms
Release TimeAC: ≤30ms, DC: ≤20ms
Insulation Resistance1000MΩ @ 500VDC

Dielectric Strength (1 min):

Withstand Voltage TestValue
Between Same Pole Contacts1000VAC
Between Opposite Pole Contacts1500VAC
Between Coil and Contact1500VAC

Environmental & Mechanical Specifications:

ParameterValue
Operating Temperature–30°C to +65°C
Humidity5% to 85% RH
Atmospheric Pressure86–106 kPa
Vibration Resistance10–55Hz, 1.0mm double amplitude
Impact Stability98 m/s²
Impact Strength980 m/s²

Physical Specifications:

Parameter1C2C
Dimensions (L × W × H)35mm × 35mm × 53mm35mm × 35mm × 53mm
WeightApprox. 88gApprox. 90g
Terminal TypePlug-inPlug-in

No relay products that meet your requirements were found. Please let us know, as we support customization based on your needs.

 
 

Frequently Asked Questions

Can I directly replace an Omron or Schneider relay with an MG relay?

Yes, the pin layout follows the same international standard for direct replacement, but you should verify the coil voltage and mounting dimensions match.

Yes, it’s more reliable against vibration-induced loosening and can reduce installation time by about 60%.

MG relays are designed for a wide operating temperature range, typically from -40°C to +70°C, ensuring reliable operation in harsh environments.

What international certifications do your relays have?

MG relays carry comprehensive global approvals including UL (North America), CE, TUV, VDE (Europe), and comply with RoHS 2.0 & REACH environmental standards, ensuring smooth export for your end equipment.

Electromechanical relays offer two key advantages: true physical isolation (zero leakage current when off) for safety, and superior surge withstand capability, making them more robust for harsh industrial power environments.

It uses a magnetic field to stretch and extinguish the powerful spark (arc) created when breaking a high DC current, preventing the contacts from welding together and significantly extending relay life.

Contact Us Now

    Scroll to Top